US accessibility

Accessible Storage in Hotel Guest Rooms and Public Spaces: What ADA Sections 225, 811 and 308 Say About Closets, Shelves, Lockers and Reach Ranges

One of each type, the reach ranges and the clear floor space, read from the text of sections 225, 811, 308 and 309

A guest room schedule lists wardrobes, shelves, drawers and hooks; a changing room or a staff area adds lockers. The ADA Accessibility Standards do not name any of these items by model or size. They say how many of each type of storage have to be reachable, and what reachable means: a clear floor space beside the element and a range of heights for the parts a person uses.

This article reads section 225 on storage, section 811 on storage elements, the reach ranges in section 308, the clear floor space and operable parts in sections 305 and 309, and the storage lines in sections 803, 804 and 806, as published on the US Access Board website, which we read on 24 October 2026. FBM Furniture works with companies only: Developers · General Contractors · Builders · Commercial Project Owners · Interior Design & Construction Companies · FF&E Solution Providers. It sets out what the text says and does not decide whether any wardrobe, shelf or locker complies. We did not read the storage provisions for residential dwelling units, the Department of Justice regulation itself, or any state or local code, which can add to or replace these requirements; your architect or accessibility consultant confirms what applies to the project. Our earlier notes read guest rooms (sections 224 and 806) and routes and protruding objects (sections 307, 402 and 403).

What section 225 says has to comply

Section 225.2 is one sentence: “Where storage is provided in accessible spaces, at least one of each type shall comply with 811.” The Advisory explains the unit of counting. Types of storage include, but are not limited to, closets, cabinets, shelves, clothes rods, hooks and drawers, and where provided, at least one of each type must be within the reach ranges specified in section 308. It adds that it is permissible to install additional storage outside the reach ranges.

The text therefore counts by type, not by quantity. A room with a hanging rod, two shelves and a drawer unit has three types, the rod, the shelf and the drawer, and at least one of each has to comply with section 811. A room with ten shelves and one rod needs one shelf and the rod.

Lockers have their own rule in section 225.2.1: where lockers are provided, “at least 5 percent, but no fewer than one of each type, shall comply with 811”. The Advisory says that different types of lockers may include full-size and half-size lockers, as well as those specifically designed for storage of various sports equipment. Self-service shelving, the library or store shelf, has a different rule in section 225.2.2: it shall be located on an accessible route complying with section 402, and “self-service shelving shall not be required to comply with 308”.

What section 811 asks of a storage element

Section 811 is short. It has three requirements for a storage element that must comply:

  • Clear floor space (811.2). A clear floor or ground space complying with section 305 is provided.
  • Height (811.3). The storage element complies with at least one of the reach ranges in section 308.
  • Operable parts (811.4). Operable parts comply with section 309.

Two other provisions use the same section. Section 804.5, for kitchens and kitchenettes, says at least 50 percent of shelf space in storage facilities shall comply with 811. And the Advisory to section 806.2, on transient lodging guest rooms, says that the requirements in section 806.2 do not include requirements common to all accessible spaces; for example, closets in guest rooms must comply with the applicable provisions for storage specified in scoping. That is the route from a hotel guest room closet back to section 225.2 and section 811.

The reach ranges in section 308

Section 811.3 sends the height question to section 308, which sets the reach by the direction of the reach and by what is in the way.

ProvisionReachWhat the text sets
308.2.1Forward, unobstructedHigh reach 48 inches (1220 mm) maximum; low reach 15 inches (380 mm) minimum above the finish floor
308.2.2Forward, over an obstructionThe clear floor space extends beneath the element for a distance not less than the reach depth. High reach 48 inches maximum where the reach depth is 20 inches (510 mm) maximum; where the depth exceeds 20 inches, high reach 44 inches (1120 mm) maximum and reach depth 25 inches (635 mm) maximum
308.3.1Side, unobstructedParallel approach; high reach 48 inches maximum, low reach 15 inches minimum; an obstruction between the clear floor space and the element is permitted where its depth is 10 inches (255 mm) maximum
308.3.2Side, over an obstructionObstruction 34 inches (865 mm) high maximum and 24 inches (610 mm) deep maximum; high reach 48 inches maximum for a reach depth of 10 inches maximum, and 46 inches (1170 mm) maximum for a reach depth up to 24 inches

In each case where the reach is over an obstruction, the numbers change with the depth of the obstruction. A shelf behind a countertop, a hanging rod behind a deep shelf above a drawer unit, and a shelf set back in a wardrobe are all reaches over something, and the table shows why the same height can pass at one depth and fail at another.

The Advisory to 308.1 adds a table for building elements such as coat hooks, lockers and operable parts designed for use primarily by children. These dimensions apply to either forward or side reaches, and the Advisory states that accessible elements and operable parts designed for adult use, or for children over age 12, can be located outside these ranges but must be within the adult reach ranges required by section 308.

Forward or side reachAges 3 and 4Ages 5 through 8Ages 9 through 12
High (maximum)36 in (915 mm)40 in (1015 mm)44 in (1120 mm)
Low (minimum)20 in (510 mm)18 in (455 mm)16 in (405 mm)

Planning a guest room wardrobe and storage package for a US project?

Send your guest room schedule and drawings. Our team will review them and get back to you.

Clear floor space and operable parts

Section 305.3 sets the clear floor space at 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Section 305.5 says that, unless otherwise specified, it is positioned for either a forward or a parallel approach to the element, and section 305.6 requires that one full unobstructed side of it adjoin an accessible route or another clear floor space. In an alcove confined on all or part of three sides, section 305.7 adds maneuvering clearance: 36 inches wide minimum where the depth exceeds 24 inches for a forward approach, and 60 inches wide minimum where the depth exceeds 15 inches for a parallel approach. A wardrobe recess in a guest room is the kind of space the alcove rule describes, which is a point to check on the plan.

Section 309 covers operable parts. They are placed within the reach ranges of section 308 (section 309.3) and “shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist”, with an activating force of 5 pounds (22.2 N) maximum (section 309.4). The Standards define an operable part as “a component of an element used to insert or withdraw objects, or to activate, deactivate, or adjust the element”. The text does not name handles or pulls. On that wording, the part that a person uses to open a door or a drawer is a component used to withdraw objects, so sections 309.3 and 309.4 are the provisions to check against it, and the design team confirms the reading.

The storage lines in other sections

Section 803 covers dressing, fitting and locker rooms. Section 803.5 says that coat hooks provided within the room “shall be located within one of the reach ranges specified in 308” and that shelves “shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground”. Section 803.4 requires a bench complying with section 903 within the room, and section 803.2 requires turning space within it.

Three details of the text are worth noting for a package. The shelf rule in 803.5 is a height band, not a reach range; hooks follow section 308. The locker count in 225.2.1 is a share of the lockers provided, with a floor of one of each type. And the rule for self-service shelving in 225.2.2 exempts it from section 308 but puts it on an accessible route.

What to put in writing before storage is specified

The text turns into a short list of items to settle with the architect or accessibility consultant before storage is ordered. Each item maps to a provision above.

  • The types of storage in each accessible space (closet, cabinet, shelf, rod, hook, drawer), so that at least one of each type can be identified as the compliant one (section 225.2).
  • For lockers, the types and the share designated as compliant, with at least one of each type (section 225.2.1).
  • The height of the compliant element against the reach range that applies, including the depth of anything the reach passes over (section 308).
  • The clear floor space in front of or beside each compliant element, and whether the element sits in an alcove (sections 305.3 to 305.7).
  • The handles, pulls and catches on compliant elements, checked against one-hand operation and the 5 pound limit (section 309.4).
  • Which state or local accessibility code applies to the project, since the Access Board text is not the only one.

Send the plans and the schedule together so that the package is quoted against the rooms it will sit in. For how FBM Furniture works with FF&E contractors, see our page for FF&E contractors.

Frequently asked questions

Does a storage closet have to be ADA accessible?

Section 225.2 says that where storage is provided in accessible spaces, at least one of each type shall comply with section 811. The Advisory to section 806.2 states that closets in guest rooms must comply with the applicable provisions for storage specified in scoping.

What reach range applies to shelves and closet rods?

Section 811.3 requires storage elements to comply with at least one of the reach ranges in section 308. For an unobstructed forward or side reach, section 308 sets the high reach at 48 inches (1220 mm) maximum and the low reach at 15 inches (380 mm) minimum above the finish floor; reaches over an obstruction have different limits depending on its depth.

How much floor space is needed in front of an accessible storage element?

Section 811.2 requires a clear floor or ground space complying with section 305, which sets 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum, positioned for a forward or a parallel approach and adjoining an accessible route or another clear floor space.

How many lockers have to be accessible?

Section 225.2.1 requires at least 5 percent of lockers provided, but no fewer than one of each type, to comply with section 811.

What does the ADA Standards say about shelves in a dressing or locker room?

Section 803.5 requires coat hooks within one of the reach ranges in section 308 and shelves between 40 inches (1015 mm) and 48 inches (1220 mm) above the finish floor or ground.

How does FBM Furniture support a hotel guest room package?

We review the brief, collect comparable quotations and manage the package for the project. For suppliers you nominate, we charge a 5% commission; for products we source for you, we quote a direct price. Our own team performs one inspection after bulk production is complete and before shipment, and your team is welcome to attend.

Planning a guest room wardrobe and storage package for a US project?

Send your guest room schedule and drawings. Our team will review them and get back to you.